smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.2-RELEASE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron_1100_MTFDDAK512TBN
Serial Number: 171316DF72EB
LU WWN Device Id: 5 00a075 116df72eb
Firmware Version: M0MU031
User Capacity: 512,110,190,592 bytes [512 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Mar 28 11:47:38 2025 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x04) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 222) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 7) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0
5 Reallocate_NAND_Blk_Cnt 0x0032 100 100 010 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 62876
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 17
171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0
172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
173 Ave_Block-Erase_Count 0x0032 070 070 000 Old_age Always - 453
174 Unexpect_Power_Loss_Ct 0x0032 100 100 000 Old_age Always - 11
183 SATA_Interfac_Downshift 0x0032 100 100 000 Old_age Always - 0
184 Error_Correction_Count 0x0032 100 100 000 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 058 049 000 Old_age Always - 42 (Min/Max 23/51)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_ECC_Cnt 0x0032 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0
202 Percent_Lifetime_Remain 0x0030 070 070 001 Old_age Offline - 30
206 Write_Error_Rate 0x000e 100 100 000 Old_age Always - 0
246 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 178042045069
247 Host_Program_Page_Count 0x0032 100 100 000 Old_age Always - 5592214878
248 FTL_Program_Page_Count 0x0032 100 100 000 Old_age Always - 5194132887
180 Unused_Reserve_NAND_Blk 0x0033 000 000 000 Pre-fail Always - 2478
210 Success_RAIN_Recov_Cnt 0x0032 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 62876 -
# 2 Vendor (0xff) Completed without error 00% 62549 -
# 3 Vendor (0xff) Completed without error 00% 62000 -
# 4 Vendor (0xff) Completed without error 00% 61513 -
# 5 Vendor (0xff) Completed without error 00% 61165 -
# 6 Vendor (0xff) Completed without error 00% 60828 -
# 7 Vendor (0xff) Completed without error 00% 60430 -
# 8 Vendor (0xff) Completed without error 00% 60068 -
# 9 Vendor (0xff) Completed without error 00% 59562 -
#10 Vendor (0xff) Completed without error 00% 59102 -
#11 Vendor (0xff) Completed without error 00% 58641 -
#12 Vendor (0xff) Completed without error 00% 58462 -
#13 Vendor (0xff) Completed without error 00% 58318 -
#14 Vendor (0xff) Completed without error 00% 58169 -
#15 Vendor (0xff) Completed without error 00% 58024 -
#16 Short offline Completed without error 00% 57872 -
#17 Vendor (0xff) Completed without error 00% 57843 -
#18 Vendor (0xff) Completed without error 00% 57694 -
#19 Vendor (0xff) Completed without error 00% 57531 -
#20 Vendor (0xff) Completed without error 00% 57385 -
#21 Vendor (0xff) Completed without error 00% 57234 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
The above only provides legacy SMART information - try 'smartctl -x' for more