Home
DevCentral
Search
Configure Global Search
Log In
Transactions
P370
Change Details
Change Details
Old
New
Diff
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.2-RELEASE amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org ERROR: smartctl requires a device name as the final command-line argument. Use smartctl -h to get a usage summary
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.2-RELEASE amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Crucial/Micron Client SSDs Device Model: Micron_1100_MTFDDAK512TBN Serial Number: 171316DF73FF LU WWN Device Id: 5 00a075 116df73ff Firmware Version: M0MU031 User Capacity: 512,110,190,592 bytes [512 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5528 ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Mar 28 11:46:45 2025 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x04) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 186) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 7) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0 5 Reallocate_NAND_Blk_Cnt 0x0032 100 100 010 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 62876 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 17 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0 173 Ave_Block-Erase_Count 0x0032 069 069 000 Old_age Always - 467 174 Unexpect_Power_Loss_Ct 0x0032 100 100 000 Old_age Always - 11 183 SATA_Interfac_Downshift 0x0032 100 100 000 Old_age Always - 0 184 Error_Correction_Count 0x0032 100 100 000 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 057 048 000 Old_age Always - 43 (Min/Max 19/52) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_ECC_Cnt 0x0032 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 202 Percent_Lifetime_Remain 0x0030 069 069 001 Old_age Offline - 31 206 Write_Error_Rate 0x000e 100 100 000 Old_age Always - 0 246 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 185347248849 247 Host_Program_Page_Count 0x0032 100 100 000 Old_age Always - 5824636490 248 FTL_Program_Page_Count 0x0032 100 100 000 Old_age Always - 5248956291 180 Unused_Reserve_NAND_Blk 0x0033 000 000 000 Pre-fail Always - 2475 210 Success_RAIN_Recov_Cnt 0x0032 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor (0xff) Completed without error 00% 62870 - # 2 Vendor (0xff) Completed without error 00% 62533 - # 3 Vendor (0xff) Completed without error 00% 62008 - # 4 Vendor (0xff) Completed without error 00% 61514 - # 5 Vendor (0xff) Completed without error 00% 61157 - # 6 Vendor (0xff) Completed without error 00% 60816 - # 7 Vendor (0xff) Completed without error 00% 60435 - # 8 Vendor (0xff) Completed without error 00% 60073 - # 9 Vendor (0xff) Completed without error 00% 59636 - #10 Vendor (0xff) Completed without error 00% 59205 - #11 Vendor (0xff) Completed without error 00% 58776 - #12 Vendor (0xff) Completed without error 00% 58487 - #13 Vendor (0xff) Completed without error 00% 58337 - #14 Vendor (0xff) Completed without error 00% 58169 - #15 Vendor (0xff) Completed without error 00% 58025 - #16 Short offline Completed without error 00% 57872 - #17 Vendor (0xff) Completed without error 00% 57872 - #18 Vendor (0xff) Completed without error 00% 57782 - #19 Vendor (0xff) Completed without error 00% 57623 - #20 Vendor (0xff) Completed without error 00% 57460 - #21 Vendor (0xff) Completed without error 00% 57314 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.2-RELEASE amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
ERROR: smartctl requires a device name as the final command-line argument. Use smartctl -h to get a usage summary
=== START OF INFORMATION SECTION === Model Family: Crucial/Micron Client SSDs Device Model: Micron_1100_MTFDDAK512TBN Serial Number: 171316DF73FF LU WWN Device Id: 5 00a075 116df73ff Firmware Version: M0MU031 User Capacity: 512,110,190,592 bytes [512 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5528 ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Mar 28 11:46:45 2025 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x04) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 186) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 7) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0 5 Reallocate_NAND_Blk_Cnt 0x0032 100 100 010 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 62876 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 17 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0 173 Ave_Block-Erase_Count 0x0032 069 069 000 Old_age Always - 467 174 Unexpect_Power_Loss_Ct 0x0032 100 100 000 Old_age Always - 11 183 SATA_Interfac_Downshift 0x0032 100 100 000 Old_age Always - 0 184 Error_Correction_Count 0x0032 100 100 000 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 057 048 000 Old_age Always - 43 (Min/Max 19/52) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_ECC_Cnt 0x0032 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 202 Percent_Lifetime_Remain 0x0030 069 069 001 Old_age Offline - 31 206 Write_Error_Rate 0x000e 100 100 000 Old_age Always - 0 246 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 185347248849 247 Host_Program_Page_Count 0x0032 100 100 000 Old_age Always - 5824636490 248 FTL_Program_Page_Count 0x0032 100 100 000 Old_age Always - 5248956291 180 Unused_Reserve_NAND_Blk 0x0033 000 000 000 Pre-fail Always - 2475 210 Success_RAIN_Recov_Cnt 0x0032 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor (0xff) Completed without error 00% 62870 - # 2 Vendor (0xff) Completed without error 00% 62533 - # 3 Vendor (0xff) Completed without error 00% 62008 - # 4 Vendor (0xff) Completed without error 00% 61514 - # 5 Vendor (0xff) Completed without error 00% 61157 - # 6 Vendor (0xff) Completed without error 00% 60816 - # 7 Vendor (0xff) Completed without error 00% 60435 - # 8 Vendor (0xff) Completed without error 00% 60073 - # 9 Vendor (0xff) Completed without error 00% 59636 - #10 Vendor (0xff) Completed without error 00% 59205 - #11 Vendor (0xff) Completed without error 00% 58776 - #12 Vendor (0xff) Completed without error 00% 58487 - #13 Vendor (0xff) Completed without error 00% 58337 - #14 Vendor (0xff) Completed without error 00% 58169 - #15 Vendor (0xff) Completed without error 00% 58025 - #16 Short offline Completed without error 00% 57872 - #17 Vendor (0xff) Completed without error 00% 57872 - #18 Vendor (0xff) Completed without error 00% 57782 - #19 Vendor (0xff) Completed without error 00% 57623 - #20 Vendor (0xff) Completed without error 00% 57460 - #21 Vendor (0xff) Completed without error 00% 57314 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more
Continue